This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The table CCIHT_MJIMPORT (EHS: Pooled Table for Imported Measurements) is a standard table in SAP ERP. It belongs to the package CBIH.
Table | CCIHT_MJIMPORT |
Short Text | EHS: Pooled Table for Imported Measurements |
Package | CBIH |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
RECN | ✔ | Sequential Number of Data Record | ESERECN | NUMC | 20 | |
ACTN | ✔ | Sequential Number of the Change State | ESEACTN | NUMC | 20 | |
VALFR | Valid-From Date | ESEVALFR | DATS | 8 | ||
VALTO | Valid-To Date | ESEVALTO | DATS | 8 | ||
AENNR | Change Number | ESEAENNR | CHAR | 12 | AENR | |
DELFLG | Deletion Indicator | ESEDELFLG | CHAR | 1 | ||
PARKFLG | Data Record Is Inactive | ESEPARKFLG | CHAR | 1 | ||
CRDAT | Created On | ESECRDAT | DATS | 8 | ||
CRNAM | Created By | ESECRNAM | CHAR | 12 | ||
UPDDAT | Changed On | ESEUPDDAT | DATS | 8 | ||
UPDNAM | Last Changed By | ESEUPDNAM | CHAR | 12 | ||
SRSID | Source of Data | ESESRSID | CHAR | 10 | TCG56 | |
OWNID | Data Provider | ESEVENDRID | CHAR | 10 | * | |
RECNROOT | Sequential Number of Data Record | ESERECN | NUMC | 20 | ||
Include Structure: CCIHS_MJ | ||||||
OBJNR | Object number | J_OBJNR | CHAR | 22 | * | |
MJID | Measurement Number | CCIHE_MJID | CHAR | 30 | ||
MJCAT | Sampling Type | CCIHE_MJCAT | CHAR | 3 | CCIHC_MJCAT | |
MJSTAT | Status | EHSBE_STATUS | CHAR | 5 | ||
EPTYPE | Agent Type | CCIHE_EPTYPE | CHAR | 10 | CCIHV_HAZTYPE | |
EPID | Agent | CCIHE_EPID | CHAR | 20 | ||
RECNTMPWA | Reference to Assigned Work Area | CCIHE_RECNTMPWA | NUMC | 20 | ||
MJVALFR | Start of Validity of Measurement | CCIHE_MJVALFR | DATS | 8 | ||
MJVALTO | End of Validity of Measurement | CCIHE_MJVALTO | DATS | 8 | ||
MSRBGNDATE | Date of Start of Measurement | CCIHE_MSRBGNDATE | DATS | 8 | ||
MSRBGNTIME | Time of Start of Measurement | CCIHE_MSRBGNTIME | TIMS | 6 | ||
MSRENDDATE | Date of End of Measurement | CCIHE_MSRENDDATE | DATS | 8 | ||
MSRENDTIME | Time of End of Measurement | CCIHE_MSRENDTIME | TIMS | 6 | ||
MDURATION | Actual Duration of Measurement | CCIHE_MDURATION | TIMS | 6 | ||
MPLDURATION | Planned Measurement Duration | CCIHE_MPLDURATION | TIMS | 6 | ||
MEXCHANGE | Perform Conversion | CCIHE_MEXCHANGE | CHAR | 1 | ||
MSOURCEID | Sampling Location | CCIHE_MSOURCEID | CHAR | 3 | CCIHC_MSOURCE | |
MSOURCENOTE | Description for Sampling Location | CCIHE_MSOURCENOTE | CHAR | 255 | ||
FIXLOCFLG | Fixed-Location Measurement | CCIHE_FIXLOCFLG | CHAR | 1 | ||
MPERIOD | Repetition of Measurement in Months | CCIHE_MPERIOD | NUMC | 2 | ||
FLOW | Flow Quantity of Measuring Device | CCIHE_FLOW | DEC | 5 | ||
FLOWUNIT | Flow Unit | CCIHE_FLOWUNIT | UNIT | 3 | * | |
DVNR | Number of the Measuring Device | CCIHE_DVNR | CHAR | 20 | ||
MDEVTYPE | Measuring Device Type | CCIHE_DVTYPE | CHAR | 3 | CCIHC_DVTYPE | |
METHOD | Measurement Method | CCIHE_METHOD | CHAR | 5 | CCIHC_METHOD | |
MPERSON | Test Person | CCIHE_MJPERSON | CHAR | 10 | ||
MPERSONGRP | Person Group | CCIHE_PERSGRP | CHAR | 1 | ||
MPERSONNAME | Full Name of Person | CCIHE_FULLNAME | CHAR | 80 | ||
MJNOTE1 | Remarks on Measurement | CCIHE_MJNOTE | CHAR | 72 | ||
MJNOTEFLG1 | Long Text | ESELTXTFLG | CHAR | 1 | ||
MJNOTE2 | Remarks on Measurement | CCIHE_MJNOTE | CHAR | 72 | ||
MJNOTEFLG2 | Long Text | ESELTXTFLG | CHAR | 1 | ||
RESPIRATOR | Respiratory Protection | CCIHE_RESPIRATOR | CHAR | 1 | ||
SAMPLENR | Container or Filter | CCIHE_SAMPLENR | CHAR | 30 | ||
MJCOSTAC | Cost Center for Measurement Project | CCIHE_MPCOSTAC | CHAR | 10 | * | |
MJCTRAREA | Controlling Area | CCIHE_MPCTRAREA | CHAR | 4 | TKA01 | |
RECNTMJ | Reference to Partial Measurement | CCIHE_RECNTREFMJ | NUMC | 20 | ||
LIMEXCEEDFLG | Reference Value Exceeded | CCIHE_LIMEXCEEDFLG | CHAR | 1 | ||
STMFLG | Short-Term Sample | CCIHE_STMFLG | CHAR | 1 | ||
METCOASTS | Cost of Analysis | CCIHE_MCOSTS | CURR | 10 | ||
METCUKY | Currency Key for Costs | CCIHE_METCUKY | CUKY | 5 | * | |
VOLUME | Total Volume in Liters | CCIHE_VOLUME | FLTP | 16 | ||
VOLDECIMALS | Decimal Places for a Measured Physical Variable Value | CCIHE_HQVALDECIMALS | INT4 | 10 | ||
MJCOCODE | Company Code | CCIHE_MPCOCODE | CHAR | 4 | * | |
FLGEXPLOCK | Object Is in Export | CCIHE_FLGEXPLCK | CHAR | 1 | ||
OPCOND | Operation Status of Work Area/Pattern | CCIHE_OPCOND | CHAR | 3 | CCIHC_OC01 | |
IMP_DATE | Date of Import | CCIHE_IMPDATE | DATS | 8 | ||
IMP_TIME | Time of Import | CCIHE_IMPTIME | TIMS | 6 | ||
UNAME | User Name | SYUNAME | CHAR | 12 | ||
ERRORMODE | Indicator: Error or warning in an API function | ESEERRMODE | CHAR | 1 | ||
ERRORINFO | Count parameters | NUMC4 | NUMC | 4 | ||
ERRORCLASS | Message Class | SYMSGID | CHAR | 20 | * | |
ERRORPARAM | 30 Characters | CHAR30 | CHAR | 30 |