This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.

Check it out on amazon.com →

The Function Module CBIH_MP30_MP_CREATE (EHS: Anlegen von Messprojektdaten) is a standard Function Module in SAP ERP and is part of the function group CBIH_MP30 within the package CBIH.

Technical Information

Function Module CBIH_MP30_MP_CREATE
Short Text EHS: Anlegen von Messprojektdaten
Function Group CBIH_MP30
Package CBIH
Module Type Normal Module

Importing Parameters

These are the IMPORTING parameters of this function module.

Parameter Name Type Associated Type Default Value Short Text
I_ADDINF LIKE RCGADDINF Zusatzinformationen zum Objekt
I_FLG_CHECK_CLVALUE TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Bewertungsdaten prüfen
I_FLG_CHECK_ONLY TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Daten nur überprüfen
I_FLG_FILL_EXTERROR TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Erweiterte FehlerInfoTabelle befüllen
I_FLG_KEY_DATE_SWITCH_ONLY TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. nur Stichtag und Änderungsnummer wechseln
I_FLG_MJ_HEADER TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Messauftrag anlegen
I_FLG_MJ_HEADER_LTXT1 TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext 1 Messauftrag
I_FLG_MJ_HEADER_LTXT2 TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext 2 Messauftrag
I_FLG_MJ_HEADER_VAL TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Bewertungen zu Messauftrag
I_FLG_MJ_REFERENCE TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Referenzmessung anlegen
I_FLG_MJ_VALUES TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Messwerte anlegen
I_FLG_MJ_WORKAREA TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Zuordnung Arbeitsber.-Messauftrag anlegen
I_FLG_MP_EQUIPMENT TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Geräte für Projekt anlegen
I_FLG_MP_HEADER TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Messprojektkopf anlegen
I_FLG_MP_HEADER_LTXT1 TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext 1 zu Messprojektkopf
I_FLG_MP_HEADER_LTXT2 TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext 2 zu Messprojektkopf
I_FLG_MP_HEADER_VAL TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Bewertungen zu Messprojektkopf
I_FLG_MP_PLAN TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Projektplan anlegen
I_FLG_MP_PLAN_LTXT TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext Projektplan
I_FLG_MP_PLMET TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Messplan Messverfahren anlegen
I_FLG_MP_WA TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Zuordn. Arbeitsbereich-Projekt anlegen
I_FLG_MP_WA_LTXT TYPE ESP1_BOOLEAN ESP1_FALSE Kennz. Langtext Arbeitsbereich
I_VALFR LIKE RCGADDINF-VALDAT untere Zeitintervallgrenze
I_VALTO LIKE RCGADDINF-VALDAT obere Zeitintervallgrenze

Exporting Parameters

These are the EXPORTING parameters of this function module.

Parameter Name Type Associated Type Default Value Short Text
E_FLG_ERROR TYPE ESP1_BOOLEAN Kennz. Fehler beim Anlegen eines Satzes
E_FLG_LOCKFAIL TYPE ESP1_BOOLEAN Kennz. Sperre auf mind. einen Satz fehlgeschl.
E_FLG_WARNING TYPE ESP1_BOOLEAN Kennz. Warnung beim Anlegen eines Satzes

Changing Parameters

This function module does not define any CHANGING parameters.

Table Parameters

These are the TABLE parameters of this function module.

Parameter Name Type Associated Type Default Value Short Text
X_API_MP_TAB TYPE CIHMP_MP_API_TAB_TYPE Messprojektdaten

Exceptions

These are the Exceptions of this function module.

Exception Name Short Text
INTERNAL_ERROR Interner Programmfehler
INTERVAL_ACCESS_ERROR Zugriff auf Zeitintervalle ist fehlerhaft
NO_OBJECT_SPECIFIED Kein anzulegendes Objekt angegeben
PARAMETER_ERROR Kennzeichen gesetzt aber zugeh. Daten fehlen