This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The Function Module CBIH_MP30_MP_CREATE (EHS: Anlegen von Messprojektdaten) is a standard Function Module in SAP ERP and is part of the function group CBIH_MP30 within the package CBIH.
Function Module | CBIH_MP30_MP_CREATE |
Short Text | EHS: Anlegen von Messprojektdaten |
Function Group | CBIH_MP30 |
Package | CBIH |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_ADDINF | LIKE | RCGADDINF | Zusatzinformationen zum Objekt | |
I_FLG_CHECK_CLVALUE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungsdaten prüfen |
I_FLG_CHECK_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Daten nur überprüfen |
I_FLG_FILL_EXTERROR | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Erweiterte FehlerInfoTabelle befüllen |
I_FLG_KEY_DATE_SWITCH_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. nur Stichtag und Änderungsnummer wechseln |
I_FLG_MJ_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messauftrag anlegen |
I_FLG_MJ_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 Messauftrag |
I_FLG_MJ_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 Messauftrag |
I_FLG_MJ_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messauftrag |
I_FLG_MJ_REFERENCE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Referenzmessung anlegen |
I_FLG_MJ_VALUES | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messwerte anlegen |
I_FLG_MJ_WORKAREA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zuordnung Arbeitsber.-Messauftrag anlegen |
I_FLG_MP_EQUIPMENT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Geräte für Projekt anlegen |
I_FLG_MP_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messprojektkopf anlegen |
I_FLG_MP_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 zu Messprojektkopf |
I_FLG_MP_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 zu Messprojektkopf |
I_FLG_MP_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messprojektkopf |
I_FLG_MP_PLAN | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Projektplan anlegen |
I_FLG_MP_PLAN_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext Projektplan |
I_FLG_MP_PLMET | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messplan Messverfahren anlegen |
I_FLG_MP_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zuordn. Arbeitsbereich-Projekt anlegen |
I_FLG_MP_WA_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext Arbeitsbereich |
I_VALFR | LIKE | RCGADDINF-VALDAT | untere Zeitintervallgrenze | |
I_VALTO | LIKE | RCGADDINF-VALDAT | obere Zeitintervallgrenze |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_FLG_ERROR | TYPE | ESP1_BOOLEAN | Kennz. Fehler beim Anlegen eines Satzes | |
E_FLG_LOCKFAIL | TYPE | ESP1_BOOLEAN | Kennz. Sperre auf mind. einen Satz fehlgeschl. | |
E_FLG_WARNING | TYPE | ESP1_BOOLEAN | Kennz. Warnung beim Anlegen eines Satzes |
This function module does not define any CHANGING parameters.
These are the TABLE parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
X_API_MP_TAB | TYPE | CIHMP_MP_API_TAB_TYPE | Messprojektdaten |
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
INTERNAL_ERROR | Interner Programmfehler |
INTERVAL_ACCESS_ERROR | Zugriff auf Zeitintervalle ist fehlerhaft |
NO_OBJECT_SPECIFIED | Kein anzulegendes Objekt angegeben |
PARAMETER_ERROR | Kennzeichen gesetzt aber zugeh. Daten fehlen |