This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The Function Module CBIH_MP30_MP_DELETE (EHS: Löschen von Messprojekten) is a standard Function Module in SAP ERP and is part of the function group CBIH_MP30 within the package CBIH.
Function Module | CBIH_MP30_MP_DELETE |
Short Text | EHS: Löschen von Messprojekten |
Function Group | CBIH_MP30 |
Package | CBIH |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_ADDINF | LIKE | RCGADDINF | Zusatzinformationen zum Objekt | |
I_FLG_CHECK_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Daten nur überprüfen |
I_FLG_FILL_EXTERROR | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Erweiterte FehlerInfoTabelle befüllen |
I_FLG_KEY_DATE_SWITCH_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. nur Stichtag und Änderungsnummer wechseln |
I_FLG_MJ_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messauftragskopf |
I_FLG_MJ_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zusatzdaten Klassensystem Messauftrag |
I_FLG_MJ_JOIN_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Arbeitsbereiche zum Messauftrag |
I_FLG_MJ_REFERENCE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Referenzmessung |
I_FLG_MJ_VALUES | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messwerte |
I_FLG_MP_EQUIPMENT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Geräte zum Messprojekt |
I_FLG_MP_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messprojektkopf |
I_FLG_MP_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zusatzdaten |
I_FLG_MP_PLAN | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Projektplan zum Messprojekt |
I_FLG_MP_PLMET | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messplan Messverfahren |
I_FLG_MP_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Arbeitsbereiche zum Messprojekt |
I_VALFR | LIKE | RCGADDINF-VALDAT | untere Zeitintervallgrenze | |
I_VALTO | LIKE | RCGADDINF-VALDAT | obere Zeitintervallgrenze |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_FLG_ERROR | TYPE | ESP1_BOOLEAN | Kennz. Fehler beim Lesen eines Satzes | |
E_FLG_LOCKFAIL | TYPE | ESP1_BOOLEAN | Kennz. Sperre auf mind. einen Satz fehlgeseschl. | |
E_FLG_WARNING | TYPE | ESP1_BOOLEAN | Kennz. Warnung beim Lesen eines Satzes |
This function module does not define any CHANGING parameters.
These are the TABLE parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
X_API_MJ_HEADER_TAB | TYPE | CIHMJ_MJAPI_TAB_TYPE | Kopfdaten zum Messauftrag | |
X_API_MJ_HEADER_VAL_TAB | TYPE | CIH01_IHVALAPI_TAB_TYPE | Bewertungsinstanzen Messauftrag | |
X_API_MJ_JOIN_WA_TAB | TYPE | CIHMW_MJWAAPI_TAB_TYPE | Arbeitsbereiche zum Messauftrag | |
X_API_MJ_REFERENCE_TAB | TYPE | CIHMR_RFMJAPI_TAB_TYPE | Referenzmessungen zum Messauftrag | |
X_API_MJ_VALUES_TAB | TYPE | CIHMV_MJVAAPI_TAB_TYPE | Messwerte zum Messauftrag | |
X_API_MP_EQUIPMENT_TAB | TYPE | CIHPD_MPDVAPI_TAB_TYPE | Ausgegebene Geräte zum Messprojekt | |
X_API_MP_HEADER_TAB | TYPE | CIHMP_MPHAPI_TAB_TYPE | Kopfdaten zum Messprojekt | |
X_API_MP_HEADER_VAL_TAB | TYPE | CIH01_IHVALAPI_TAB_TYPE | Bewertungsinstanzen Messprojektkopf | |
X_API_MP_PLAN_TAB | TYPE | CIHPL_MPPLAPI_TAB_TYPE | Projektplan zum Messprojekt | |
X_API_MP_PLMET_TAB | TYPE | CIHMT_MPMTAPI_TAB_TYPE | Messplan Messverfahren | |
X_API_MP_WA_TAB | TYPE | CIHPW_MPWAAPI_TAB_TYPE | Arbeitsbereiche zum Messprojekts |
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
CONVMODE_SET_FAILED | Fehler Sprachenunterstützung |
INTERNAL_ERROR | Interner Fehler oder Customizing-Fehler |
INTERVAL_ACCESS_ERROR | Zugriff auf Zeitintervalle ist fehlerhaft |
NO_OBJECT_SPECIFIED | In der Kopftabelle wurden keine Objekte angeg. |
PARAMETER_ERROR | Kennzeichen gesetzt aber zugeh. Tabelle fehlt |