This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The Function Module CBIH_MP30_MP_READ (EHS: Lesen von Messprojektdaten) is a standard Function Module in SAP ERP and is part of the function group CBIH_MP30 within the package CBIH.
Function Module | CBIH_MP30_MP_READ |
Short Text | EHS: Lesen von Messprojektdaten |
Function Group | CBIH_MP30 |
Package | CBIH |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_ADDINF | LIKE | RCGADDINF | Zusatzinformationen zum Objekt | |
I_FLG_FILL_EXTERROR | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Erweiterte FehlerInfoTabelle befüllen |
I_FLG_KEY_DATE_SWITCH_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. nur Stichtag und Änderungsnummer wechseln |
I_FLG_MJ_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messauftragskopf |
I_FLG_MJ_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 zu Messauftrag |
I_FLG_MJ_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 zu Messauftrag |
I_FLG_MJ_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messauftrag |
I_FLG_MJ_JOIN_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Arbeitsbereiche zum Messauftrag |
I_FLG_MJ_REFERENCE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Referenzmessung |
I_FLG_MJ_VALUES | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messwerte |
I_FLG_MP_EQUIPMENT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Geräte zum Messprojekt |
I_FLG_MP_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messprojektkopf lesen |
I_FLG_MP_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 zu Messprojektkopf |
I_FLG_MP_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 zu Messprojektkopf |
I_FLG_MP_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messprojektkopf |
I_FLG_MP_PLAN | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Projektplan zum Messprojekt |
I_FLG_MP_PLAN_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext zu Projektplan |
I_FLG_MP_PLMET | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messplan Messverfahren |
I_FLG_MP_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Arbeitsbereiche zum Messprojekt |
I_FLG_MP_WA_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext zu Arbeitsbereich |
I_FLG_NO_AUTH_CHECK | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Berechtigungsprüfungen ausschalten |
I_FLG_READ_ALL_CHARACT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Alle Bewertungen lesen |
I_FLG_RETURN_WHOLE_INTERVAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. das ganze Zeitintervall lesen |
I_FLG_SORT_PROP_DATA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen sortiert zurückgeben |
I_LANGU | TYPE | LANGU | SY-LANGU | Sprachenschlüssel Klassensystemdaten |
I_SCENARIO | TYPE | ESPAP_SCENARIO_TYPE | Sperrszenario | |
I_VALFR | LIKE | RCGADDINF-VALDAT | obere Zeitintervallgrenze | |
I_VALTO | LIKE | RCGADDINF-VALDAT | untere Zeitintervallgrenze |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_FLG_ERROR | TYPE | ESP1_BOOLEAN | Kennz. Fehler beim Lesen eines Satzes | |
E_FLG_LOCKFAIL | TYPE | ESP1_BOOLEAN | Kennz. Sperre auf mind. einen Satz fehlgeseschl. | |
E_FLG_WARNING | TYPE | ESP1_BOOLEAN | Kennz. Warnung beim Lesen eines Satzes |
This function module does not define any CHANGING parameters.
These are the TABLE parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_API_MJ_HEADER_LTXT1_TAB | TYPE | CIHMJ_MJLTAPI_TAB_TYPE | Langtext 1 Messauftrag | |
E_API_MJ_HEADER_LTXT2_TAB | TYPE | CIHMJ_MJLTAPI_TAB_TYPE | Langtext 2 Messauftrag | |
E_API_MJ_HEADER_PROP_TAB | TYPE | CIH01_IHPRAPI_TAB_TYPE | Bewertungsdaten zum Messauftrag | |
E_API_MJ_HEADER_TAB | TYPE | CIHMJ_MJAPI_TAB_TYPE | Kopfdaten zum Messauftrag | |
E_API_MJ_HEADER_VAL_TAB | TYPE | CIH01_IHVALAPI_TAB_TYPE | Bewertungsinstanzen Messauftrag | |
E_API_MJ_JOIN_WA_TAB | TYPE | CIHMW_MJWAAPI_TAB_TYPE | Arbeitsbereiche zum Messauftrag | |
E_API_MJ_REFERENCE_TAB | TYPE | CIHMR_RFMJAPI_TAB_TYPE | Referenzmessungen zum Messauftrag | |
E_API_MJ_VALUES_TAB | TYPE | CIHMV_MJVAAPI_TAB_TYPE | Messwerte zum Messauftrag | |
E_API_MP_EQUIPMENT_TAB | TYPE | CIHPD_MPDVAPI_TAB_TYPE | Ausgegebene Geräte zum Messprojekt | |
E_API_MP_HEADER_LTXT1_TAB | TYPE | CIHMP_MPLTAPI_TAB_TYPE | Langtext 1 Messprojektkopf | |
E_API_MP_HEADER_LTXT2_TAB | TYPE | CIHMP_MPLTAPI_TAB_TYPE | Langtext 2 Messprojektkopf | |
E_API_MP_HEADER_PROP_TAB | TYPE | CIH01_IHPRAPI_TAB_TYPE | Bewertungsdaten zum Messprojektkopf | |
E_API_MP_HEADER_VAL_TAB | TYPE | CIH01_IHVALAPI_TAB_TYPE | Bewertungsinstanzen Messprojektkopf | |
E_API_MP_PLAN_LTXT_TAB | TYPE | CIHPL_MPPLTAPI_TAB_TYPE | Langtext Projektplan | |
E_API_MP_PLAN_TAB | TYPE | CIHPL_MPPLAPI_TAB_TYPE | Projektplan zum Messprojekt | |
E_API_MP_PLMET_TAB | TYPE | CIHMT_MPMTAPI_TAB_TYPE | Messplan Messverfahren | |
E_API_MP_WA_LTXT_TAB | TYPE | CIHPW_MPWLTAPI_TAB_TYPE | Langtext Arbeitsbereich | |
E_API_MP_WA_TAB | TYPE | CIHPW_MPWAAPI_TAB_TYPE | Arbeitsbereiche zum Messprojekts | |
X_API_MP_HEADER_TAB | TYPE | CIHMP_MPHAPI_TAB_TYPE | Kopfdaten zum Messprojekt |
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
CONVMODE_SET_FAILED | Fehler Sprachenunterstützung |
INTERNAL_ERROR | Interner Fehler oder Customizing-Fehler |
INTERVAL_ACCESS_ERROR | Zugriff auf Zeitintervalle ist fehlerhaft |
NO_OBJECT_SPECIFIED | In der Kopftabelle wurden keine Objekte angeg. |
PARAMETER_ERROR | Kennzeichen gesetzt aber zugeh. Tabelle fehlt |