This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The Function Module QEEM_INT_CANCEL_VALUE (Interne Schnittstelle QM-Ergebniserfassung, Stornieren Urwert) is a standard Function Module in SAP ERP and is part of the function group QEEM within the package QE.
Function Module | QEEM_INT_CANCEL_VALUE |
Short Text | Interne Schnittstelle QM-Ergebniserfassung, Stornieren Urwert |
Function Group | QEEM |
Package | QE |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_KZ_SERIALNR | LIKE | QM00-QKZ | SPACE | Ind. serial number has priority |
I_PROBENR | LIKE | QAISE-PROBENR | '000000' | Sample number (if characteristic with sample) |
I_RUECKMELNR | LIKE | QAIMR-RUECKMELNR | Completion confirmation number of the characteristic | |
I_SERIALNR | LIKE | QAISE-SERIALNR | SPACE | Serial number |
I_STUECKNR | LIKE | QAISE-STUECKNR | '0000' | Individual part number |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_PROBENR | LIKE | QAISE-PROBENR | Sample number output |
This function module does not define any CHANGING parameters.
This function module does not define any TABLE parameters.
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
ENQUEUE_ERROR | Error when blocking the characteristic |
ERROR_VALUATION_MODULE | Error in the valuation of the characteristic/ sample |
FEATURE_ALREADY_LOCKED | Characteristic is already blocked |
FEATURE_NOT_FOUND | Characteristic for the completion confirmation number does not exist |
INSP_POINT_NOT_FOUND | Inspection point not found |
LOT_NOT_FOUND | Inspection lot could not be found |
LOT_WRONG_STATUS | Inspection lot has incorrect processing status |
NO_AUTHORITY_INSPECTION_TYPE | No authorization for inspection type |
NO_AUTHORITY_OPERATION | No authorization for the operation |
OPERATION_NOT_FOUND | Inspection operation could not be found |
QIER_ERROR_MESSAGE | Fehler aufgetreten und bereits protokolliert |
SAMPLE_NOT_FOUND | Sample for the characteristic could not be found |
SERIALNO_MISSING | Serial number missing |
STATUS_ERROR | Error in the status conversion of the characteristic |
VALUE_NOT_FOUND | Value could not be found |