This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The Function Module ST_STAGE_DEADLINE_CHECK (Abschnitt: Überprüft Termindaten auf Konsistenz) is a standard Function Module in SAP ERP and is part of the function group STAG within the package VTR.
Function Module | ST_STAGE_DEADLINE_CHECK |
Short Text | Abschnitt: Überprüft Termindaten auf Konsistenz |
Function Group | STAG |
Package | VTR |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_DATE_END | LIKE | VTTS-DPTEN | Ende: Datum | |
I_DATE_START | LIKE | VTTS-DPTBG | Beginn: Datum | |
I_DURATION_EFFECTIVE | LIKE | VTTS-FAHZTD | Effektive Dauer | |
I_DURATION_OVERALL | LIKE | VTTS-GESZTD | Gesamtdauer | |
I_TIME_END | LIKE | VTTS-UPTEN | Ende: Uhrzeit | |
I_TIME_START | LIKE | VTTS-UPTBG | Beginn: Uhrzeit | |
OPT_CHECK_ALL | LIKE | 'X' | Alles Überprüfen | |
OPT_CHECK_DURATION | LIKE | SPACE | Zeitdauern überprüfen | |
OPT_CHECK_DURATION_EFFCT_CONS | LIKE | SPACE | Überprüfen, ob Eff. Dauer konsistent | |
OPT_CHECK_DURATION_OVRLL_CONS | LIKE | SPACE | Überprüfen, ob Gesamtdauer konsistent | |
OPT_CHECK_END | LIKE | SPACE | Ende überprüfen | |
OPT_CHECK_START | LIKE | SPACE | Beginn überprüfen | |
OPT_CHECK_START_BEFORE_END | LIKE | SPACE | Überprüfen, ob Beginn vor Ende liegt | |
OPT_STOP_AFTER_FIRST_ERROR | LIKE | 'X' | Nach erstem Fehler aufhören |
This function module does not define any EXPORTING parameters.
These are the CHANGING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
C_NUMBER_OF_ERRORS | TYPE | I | Anzahl Fehler |
This function module does not define any TABLE parameters.
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
DATE_END_BEFORE_START | Ende-Datum liegt vor Beginn-Datum |
DATE_END_INVALID | Ende: Datum ungültig |
DATE_START_INVALID | Beginn: Datum ungültig |
DURATION_EFFECTIVE_INCONS | Eff. Dauer mit den anderen Daten nicht konsist. |
DURATION_EFFECTIVE_INVALID | Effektive Dauer ungültig |
DURATION_OVERALL_INCONS | Gesamtdauer mit den anderen Daten nicht konsist. |
DURATION_OVERALL_INVALID | Gesamtdauer ungültig |
ONE_OR_MORE_ERRORS | Ein oder mehr Fehler aufgetreten |
TIME_END_BEFORE_START | Ende-Uhrzeit liegt vor Beginn-Uhrzeit |
TIME_END_INVALID | Ende: Uhrzeit ungültig |
TIME_START_INVALID | Beginn: Uhrzeit ungültig |