This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The table QASV (Sample specifications for inspection processing) is a standard table in SAP ERP. It belongs to the package QE.
Table | QASV |
Short Text | Sample specifications for inspection processing |
Package | QE |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDANT | ✔ | Client | MANDT | CLNT | 3 | T000 |
PRUEFLOS | ✔ | Inspection Lot Number | QPLOS | NUMC | 12 | QALS |
VORGLFNR | ✔ | Current Node Number from Order Counter APLZL | QLFNKN | NUMC | 8 | |
MERKNR | ✔ | Inspection Characteristic Number | QMERKNRP | NUMC | 4 | |
PROBENR | ✔ | Sample Number | QPROBENR | NUMC | 6 | |
ERSTELLER | Name of User Who Created the Data Record | QERSTELLER | CHAR | 12 | ||
ERSTELLDAT | Date on Which the Data Record Was Created | QDATUMERST | DATS | 8 | ||
AENDERER | Name of User who Most Recently Changed the Data Record | QAENDERER | CHAR | 12 | ||
AENDERDAT | Date on Which Data Record Was Changed | QDATUMAEND | DATS | 8 | ||
SATZSTATUS | Specification Record Status | QSTATUS | CHAR | 1 | TQ76 | |
ANNAHMEZ | Acceptance Number | QANNAHMEZ | INT2 | 5 | ||
RUECKWEZ | Rejection Number | QRUECKWEZ | INT2 | 5 | ||
KFAKTORNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
KFAKTOR | K-Factor for a Variable Inspection | QKFAKTOR | FLTP | 16 | ||
ANTVERF | Fraction Calculation | QEANTVERF | CHAR | 2 | TQ72 | |
BEWREGEL | Valuation Rule | QBEWERT | CHAR | 2 | QDFM | |
FAKPLANME | Factor for Converting MatUnitOfMeasure to SampUnitOfMeasure | QUMREN | FLTP | 16 | ||
FAKPROBME | Factor for Converting SampUnitOfMeasure to MatUnitOfMeasure | QUMRENPME | FLTP | 16 | ||
PROBMGFAK | Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) | QPROBEFAK | DEC | 5 | ||
PROBEMGEH | Sample Unit of Measure | QPROBME | UNIT | 3 | T006 | |
STIPROUMF | Sample Size that Must Be Inspected | QSTIPROUMF | INT4 | 10 | ||
PRUEFUMF | Quantity to Be Inspected | QPRUEFUMF | QUAN | 13 | ||
MENGENEINH | Base Unit of Measure for the Sample Unit | QPROBEMGEH | UNIT | 3 | T006 | |
QRKNR | Control Chart Number | QQRKNR | NUMC | 12 | QASH | |
PRSTUFE | Inspection Stage | QPRSTUFE | NUMC | 4 | QDPS | |
PRSCHAERFE | Inspection Severity | QPRSCHAERF | NUMC | 3 | QDEP |