This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table QDSV (Sampling procedure) is a standard table in SAP ERP. It belongs to the package QD.
Table | QDSV |
Short Text | Sampling procedure |
Package | QD |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
STICHPRVER | ✔ | Sampling Procedure | QSTPRVER | CHAR | 8 | |
STICHPRART | Sampling Type | QSTPRART | CHAR | 3 | QDSA | |
BEWERTMOD | Valuation Mode | QBEWMOD | CHAR | 3 | QDBM | |
KZOHI | No Inspection Stage Change | QKZOHI | CHAR | 1 | ||
KZUMFS | Multiple Samples | QKZUMFS | CHAR | 1 | ||
KZNOCUT | Sample Size Not Reduced | QKZNOCUT | CHAR | 1 | ||
STPRANZ | Number of Samples for Multiple Samples | QSTPRANZ | INT1 | 3 | ||
STPRUMF | Number of Sampling Units in a Sample | QSTPRUMF | INT4 | 10 | ||
ANNAHMEZ | Acceptance Number | QANNAHMEZ | INT2 | 5 | ||
KFAKTOR | K-Factor for a Variable Inspection | QKFAKTOR | FLTP | 16 | ||
KFAKTORNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
KZNVWSV | Sampling Procedure Cannot Be Used | QKZNVWSV | CHAR | 1 | ||
KZVWSVPL | Sampling Procedure Is Used in Inspection Plan | QKZVWSVPL | CHAR | 1 | ||
FBKEY | Identifier for the Sample Determination Rule | QFBKEY | CHAR | 2 | QDFB | |
FBKEYMFS | Code for Valuation Rule for Independent Multiple sampling | QFBKEYMFS | CHAR | 2 | QDFM | |
STPRPLAN | Sampling Scheme in Sampling Procedure | QSTPRPLANV | CHAR | 3 | QDPK | |
PRSCHAERFE | Inspection Severity in Sampling Procedure | QPRSCHAERV | NUMC | 3 | QDEP | |
AQLWERT | AQL Value in Sampling Procedure | QAQLWERTV | DEC | 7 | ||
PROZUMF | Sample Size as Percentage of Lot Size | QPROZUMF | FLTP | 16 | ||
PROZUMFNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
PROZAZL | Acceptance Number as Percentage of Sample Size | QPROZAZL | FLTP | 16 | ||
PROZAZLNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
ERSTELLER | Name of User Who Created the Data Record | QERSTELLER | CHAR | 12 | ||
AENDERER | Name of User who Most Recently Changed the Data Record | QAENDERER | CHAR | 12 | ||
ERSTELLDAT | Date on Which the Data Record Was Created | QDATUMERST | DATS | 8 | ||
AENDERDAT | Date on Which Data Record Was Changed | QDATUMAEND | DATS | 8 | ||
KZRAST | Indicator: Sampling Procedure for Inspection Points | QKZRAST | CHAR | 1 | ||
RASTER | Inspection Frequency (Only for Inspection with Insp. Points) | QRASTER | NUMC | 3 | ||
QRKART | Control Chart Type | QQRKART | CHAR | 3 | QPSH |