This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The table QDSV (Sampling procedure) is a standard table in SAP ERP. It belongs to the package QD.
Table | QDSV |
Short Text | Sampling procedure |
Package | QD |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
STICHPRVER | ✔ | Sampling Procedure | QSTPRVER | CHAR | 8 | |
STICHPRART | Sampling Type | QSTPRART | CHAR | 3 | QDSA | |
BEWERTMOD | Valuation Mode | QBEWMOD | CHAR | 3 | QDBM | |
KZOHI | No Inspection Stage Change | QKZOHI | CHAR | 1 | ||
KZUMFS | Multiple Samples | QKZUMFS | CHAR | 1 | ||
KZNOCUT | Sample Size Not Reduced | QKZNOCUT | CHAR | 1 | ||
STPRANZ | Number of Samples for Multiple Samples | QSTPRANZ | INT1 | 3 | ||
STPRUMF | Number of Sampling Units in a Sample | QSTPRUMF | INT4 | 10 | ||
ANNAHMEZ | Acceptance Number | QANNAHMEZ | INT2 | 5 | ||
KFAKTOR | K-Factor for a Variable Inspection | QKFAKTOR | FLTP | 16 | ||
KFAKTORNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
KZNVWSV | Sampling Procedure Cannot Be Used | QKZNVWSV | CHAR | 1 | ||
KZVWSVPL | Sampling Procedure Is Used in Inspection Plan | QKZVWSVPL | CHAR | 1 | ||
FBKEY | Identifier for the Sample Determination Rule | QFBKEY | CHAR | 2 | QDFB | |
FBKEYMFS | Code for Valuation Rule for Independent Multiple sampling | QFBKEYMFS | CHAR | 2 | QDFM | |
STPRPLAN | Sampling Scheme in Sampling Procedure | QSTPRPLANV | CHAR | 3 | QDPK | |
PRSCHAERFE | Inspection Severity in Sampling Procedure | QPRSCHAERV | NUMC | 3 | QDEP | |
AQLWERT | AQL Value in Sampling Procedure | QAQLWERTV | DEC | 7 | ||
PROZUMF | Sample Size as Percentage of Lot Size | QPROZUMF | FLTP | 16 | ||
PROZUMFNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
PROZAZL | Acceptance Number as Percentage of Sample Size | QPROZAZL | FLTP | 16 | ||
PROZAZLNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
ERSTELLER | Name of User Who Created the Data Record | QERSTELLER | CHAR | 12 | ||
AENDERER | Name of User who Most Recently Changed the Data Record | QAENDERER | CHAR | 12 | ||
ERSTELLDAT | Date on Which the Data Record Was Created | QDATUMERST | DATS | 8 | ||
AENDERDAT | Date on Which Data Record Was Changed | QDATUMAEND | DATS | 8 | ||
KZRAST | Indicator: Sampling Procedure for Inspection Points | QKZRAST | CHAR | 1 | ||
RASTER | Inspection Frequency (Only for Inspection with Insp. Points) | QRASTER | NUMC | 3 | ||
QRKART | Control Chart Type | QQRKART | CHAR | 3 | QPSH |