This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table QPMK (Inspection characteristic master) is a standard table in SAP ERP. It belongs to the package QA.
Table | QPMK |
Short Text | Inspection characteristic master |
Package | QA |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
ZAEHLER | ✔ | Plant for the Master Inspection Characteristic | QZAEHLER | CHAR | 4 | |
MKMNR | ✔ | Master Inspection Characteristics | QMERKNR | CHAR | 8 | |
VERSION | ✔ | Version Number of the Master Inspection Characteristic | QVERSNRMK | CHAR | 6 | |
WERKS | Plant | WERKS_D | CHAR | 4 | T001W | |
GUELTIGAB | Valid-From Date | DATUV | DATS | 8 | ||
SORTFELD | Search Field | QSORTFELD | CHAR | 40 | ||
CHARACT_ID1 | Characteristic Description for Quality Data Exchange | QCHARACT_ID1 | CHAR | 40 | ||
LOEKZ | Status of Master Record | QLOESCHKZ | CHAR | 1 | ||
LSPER | Data Record Is Used | QVERW | CHAR | 1 | ||
KONSISTENT | Copy Model/Reference Characteristic | QVOLLST | CHAR | 1 | ||
AUTOR | Name of User Who Created the Data Record | QERSTELLER | CHAR | 12 | ||
DATES | Date on Which the Data Record Was Created | QDATUMERST | DATS | 8 | ||
AEAUT | Name of User who Most Recently Changed the Data Record | QAENDERER | CHAR | 12 | ||
DATAE | Date on Which Data Record Was Changed | QDATUMAEND | DATS | 8 | ||
STEUERKZ | Cntrl Indicator String for Insp. Char./Master Insp. Char. | QMKCONTROL | CHAR | 30 | ||
MERKGEW | Weighting of the Characteristic | QMERKGEW | CHAR | 2 | TQ17A | |
PRFQL | Inspector Qualification | QPRQUALIF | CHAR | 5 | TQ11 | |
DUMMY10 | Text Line for Additional Information | QTXT10 | CHAR | 10 | ||
DUMMY20 | Text Line for Additional Information | QTXT20 | CHAR | 20 | ||
DUMMY40 | Text Line for Additional Information | QTXT40 | CHAR | 40 | ||
QAUTH | Authorization Group QM Basic Data | QMASTAUTH | CHAR | 8 | TQ01D | |
TOLERANZSL | Tolerance Key | QTOLERANZ | CHAR | 4 | TQ29 | |
STELLEN | Number of Places to the Right of a Decimal Point (Accuracy) | QSTELLEN | INT1 | 3 | ||
MASSEINHSW | Unit of Measurement, in Which Quantitative Data Is Stored | QMASSEH | UNIT | 3 | T006 | |
SOLLWERT | Target Value for a Quantitative Characteristic | QSOLLWERTE | FLTP | 16 | ||
SOLLWNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERANZOB | Upper Specification Limit | QTOLOB | FLTP | 16 | ||
TOLOBNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERANZUN | Lower Tolerance Limit | QTOLUN | FLTP | 16 | ||
TOLUNNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
KLASANZAHL | Number of Value Classes for Inspection Results | QKLASSZAHL | INT1 | 3 | ||
KLASBREITE | Class Width | QKLASSBR | FLTP | 16 | ||
KLASBRNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
KLASMITTE | Class Midpoint | QKLASSMIT | FLTP | 16 | ||
KLASMINI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
GRENZEOB1 | First Upper Specification Limit | QGRENZOB1 | FLTP | 16 | ||
GRENZOB1NI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
GRENZEUN1 | First Lower Specification Limit | QGRENZUN1 | FLTP | 16 | ||
GRENZUN1NI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
GRENZEOB2 | Second Upper Specification Limit | QGRENZOB2 | FLTP | 16 | ||
GRENZOB2NI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
GRENZEUN2 | Second Lower Specification Limit | QGRENZUN2 | FLTP | 16 | ||
GRENZUN2NI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
PLAUSIOBEN | Upper Plausibility Limit | QPLAUSIOB | FLTP | 16 | ||
PLAUSIOBNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
PLAUSIUNTE | Lower Plausibility Limit | QPLAUSIUN | FLTP | 16 | ||
PLAUSIUNNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERWEIOB | Change to Upper Specification Limit | QTOLWOB | FLTP | 16 | ||
TOLWOBNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERWEIUN | Change to Lower Specification Limit | QTOLWUN | FLTP | 16 | ||
TOLWUNNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERWAB | Date from Which the Tolerance Change Is Valid | QTOLWAB | DATS | 8 | ||
TOLERWBIS | Date Until Which the Tolerance Change Is Valid | QTOLWBIS | DATS | 8 | ||
CODEGR9U | Defect Code Group for Rejection at Lower Tolerance | QCODEGRPU | CHAR | 8 | QPGR | |
CODE9U | Defect Code for Rejection at Lower Specification Limit | QCODEU | CHAR | 4 | QPCD | |
CODEVR9U | Version Number | QVERSNR | CHAR | 6 | ||
CODEGR9O | Defect Code Group for Rejection at Upper Tolerance | QCODEGRPO | CHAR | 8 | QPGR | |
CODE9O | Defect Code for Rejection at Upper Specification Limit | QCODEO | CHAR | 4 | QPCD | |
CODEVR9O | Version Number | QVERSNR | CHAR | 6 | ||
ATINN | Internal characteristic | ATINN | NUMC | 10 | * | |
EEANTVERF | Fraction Calculation | QEANTVERF | CHAR | 2 | TQ72 | |
CODEGRQUAL | Defect Code Group for General Rejection | QCODEGRPQL | CHAR | 8 | QPGR | |
CODEQUAL | Defect Code for Rejection: General | QCODEQL | CHAR | 4 | QPCD | |
INPPROC | Parameters for Input Processing in QM Results Recording | QINPPROC | CHAR | 3 | TQ71 | |
SPEC_DET_RULE | Specification Determination Rule | QASDR_SPEC_DET_RULE | CHAR | 3 | QASDRI_SPECDET | |
SPEC_DET_ACTIVE | Active Indicator for Specification Determination Rule | QASDR_SDR_ACTIVE | CHAR | 1 | ||
PARAMETER1 | Parameters for Specification Determination | QASDR_SDR_PARAMETER | CHAR | 16 | ||
PARAMETER2 | Parameters for Specification Determination | QASDR_SDR_PARAMETER | CHAR | 16 |