This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table QPRVP (Sample-drawing items) is a standard table in SAP ERP. It belongs to the package QPR.
Table | QPRVP |
Short Text | Sample-drawing items |
Package | QPR |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
PRZIEHVERF | ✔ | Sample-Drawing Procedure | QPRZIEHVER | CHAR | 8 | QPRVK |
VERSION | ✔ | Version No. of the Sample-Drawing Procedure | QVERSNPRZV | CHAR | 6 | |
POSNRPRZV | ✔ | Item Number in Sample-Drawing Procedure | QZAEHLPRZV | NUMC | 4 | |
LOSGEBEH | Lot Container | QGEBEH | UNIT | 3 | T006 | |
PROBNRPL | Highest Partial Sample No. Valid for Instruction | QPROBNRBIS | NUMC | 3 | ||
GEBINDE1 | Physical-Sample Container for Drawing Primary Sample | QGEBINDE1 | CHAR | 6 | TQ42 | |
STPRPLAN1 | Sampling Scheme for Primary Sample Stage of Sample Drawing | QSTPRPLAN1 | CHAR | 3 | QDPK | |
PRSCHAERF1 | Insp. Severity in Samp.-Draw. Proc. at Primary Sample Stage | QPRSCHAER1 | NUMC | 3 | QDEP | |
AQLWERT1 | AQL Value in Primary Sample Stage | QAQLWERT1 | DEC | 7 | ||
PRANZ1 | Fixed No. of Physical Samples for Primary Sample Stage | QPRANZ1 | INT1 | 3 | ||
FAKTORPR1 | Factor for Determining the Sample Size of a Primary Sample | QFAKTORPR1 | INT1 | 3 | ||
FORMEL1 | Formula Field for the Number of Samples | QFORMELP | CHAR | 60 | ||
GEBINDER | Physical-Sample Container for Reserve Sample | QGEBINDER | CHAR | 6 | TQ42 | |
ANZRUECKL | Number of Reserve Samples | QANZRUECKL | INT1 | 3 | ||
UMFRUECKL | Size of Reserve Sample | QUMFRUECKL | QUAN | 13 | ||
MERUECKL | Unit of Measure for Reserve Sample | QMERUECKL | UNIT | 3 | T006 | |
GEBINDE2 | Physical-Sample Container for Drawing Pooled Sample | QGEBINDE2 | CHAR | 6 | TQ42 | |
STPRPLAN2 | Sampling Scheme for Pooled Sample Stage of Sample Drawing | QSTPRPLAN2 | CHAR | 3 | QDPK | |
PRSCHAERF2 | Insp. Severity of Samp.-Proc. at Pooled Sample Stage | QPRSCHAER2 | NUMC | 3 | QDEP | |
AQLWERT2 | AQL Value in Pooled Sample Stage | QAQLWERT2 | DEC | 7 | ||
PRANZ2 | Fixed No. of Physical Samples for Pooled Sample Stage | QPRANZ2 | INT1 | 3 | ||
FAKTORPR2 | Factor for Determining the Sample Size of a Pooled Sample | QFAKTORPR2 | INT1 | 3 | ||
FORMEL2 | Formula Field for the Number of Samples | QFORMELP | CHAR | 60 | ||
ERSTELLER | Name of User Who Created the Data Record | QERSTELLER | CHAR | 12 | ||
AENDERER | Name of User who Most Recently Changed the Data Record | QAENDERER | CHAR | 12 | ||
DATUMERST | Date on Which the Data Record Was Created | QDATUMERST | DATS | 8 | ||
ZEITERST | Time Data Record Was Created | QERSTZEIT | TIMS | 6 | ||
DATUMAEND | Date on Which Data Record Was Changed | QDATUMAEND | DATS | 8 | ||
ZEITAEND | Time of Last Data Record Change | QAENZEIT | TIMS | 6 |