This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table S069 (Material Statistics (QM)) is a standard table in SAP ERP. It belongs to the package MCS.
Table | S069 |
Short Text | Material Statistics (QM) |
Package | MCS |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
SSOUR | ✔ | Statistic(s) origin | SSOUR | CHAR | 4 | |
VRSIO | ✔ | Version number in the information structure | VRSIO | CHAR | 3 | * |
SPMON | ✔ | Period to analyze - month | SPMON | NUMC | 6 | |
SPTAG | ✔ | Period to analyze - current date | SPTAG | DATS | 8 | |
SPWOC | ✔ | Period to analyze - week | SPWOC | NUMC | 6 | |
SPBUP | ✔ | Period to analyze - posting period | SPBUP | NUMC | 6 | |
MATNR | ✔ | Material Number | MATNR | CHAR | 18 | MARA |
ART | ✔ | Inspection Type | QPART | CHAR | 8 | TQ30 |
WERK | ✔ | Plant | WERKS_D | CHAR | 4 | T001W |
PERIV | Fiscal Year Variant | PERIV | CHAR | 2 | * | |
VWDAT | Pointer to administrative data | VWDAT | NUMC | 10 | ||
BASME_QM | Base Unit of Measure for The Inspection Lot Quantity | QLOSMENGEH | UNIT | 3 | T006 | |
PROME | Base Unit of Measure for the Sample Unit | QPROBEMGEH | UNIT | 3 | T006 | |
EHTAG | Lead Time Unit (Day) | QEINHTAG | UNIT | 3 | T006 | |
ZHLSELECT | Number of Summarized Inspection Lots (Without Cancellation) | QZHLSELECT | INT4 | 10 | ||
ZHLANGENS | Number of Accepted Inspection Lots (Including Skips) | QZHLANGENS | INT4 | 10 | ||
ZHLRUECK | Number of Rejected Inspection Lots | QZHLRUECK | INT4 | 10 | ||
ZHLSKIP | Number of Skipped Inspection Lots | QZHLSKIP | INT4 | 10 | ||
ZHLABBR | Number of Inspection Lots with Discontinued Inspections | QZHLABBR | INT4 | 10 | ||
ZHLOFFMK | Number of Insp. Lots with Outstanding Long-Term Characs | QZHLOFFMK | INT4 | 10 | ||
SMGSELECT | Cumulated Quantity of Summarized Inspection Lots | QSMGSELECT | QUAN | 17 | ||
SMGANGENS | Accumulated Quantity of Accepted Inspection Lots (with Skip) | QSMGANGENS | QUAN | 17 | ||
SMGRUECK | Cumulated Quantity of Rejected Inspection Lots | QSMGRUECK | QUAN | 17 | ||
SMGSKIP | Cumulated Quantity of Skipped Inspection Lots | QSMGSKIP | QUAN | 17 | ||
SMGGEPRFT | Cumulated Sample Quantity | QSMGGEPRFT | QUAN | 17 | ||
SMGGEPRFTI | Cumulated Sample Quantity (Actual) | QSMGGPRFTI | QUAN | 17 | ||
SMGDIFF | Accumulated Qty Difference Between Target Qty and Actual Qty | QSMGDIFF | QUAN | 17 | ||
SMGZERSTR | Cumulated Quantity Destroyed During Inspection | QSMGZERSTR | QUAN | 17 | ||
SMGFREIBE | Accumulated Qty that Was Posted to Unrestricted-Use Stock | QSMGFREIBE | QUAN | 17 | ||
SMGSCHRTT | Cumulated Quantity Posted to Scrap | QSMGSCHRTT | QUAN | 17 | ||
SMGSTPR | Cumulated Quantity Posted to Sample | QSMGSTPR | QUAN | 17 | ||
SMGSPERR | Cumulated Quantity Posted to Blocked Stock | QSMGSPERR | QUAN | 17 | ||
SMGRUECKL | Cumulated Quantity Posted to Reserves | QSMGRUECKL | QUAN | 17 | ||
SMGANDMAT | Cumulated Quantity that Was Posted to Another Material | QSMGANDMAT | QUAN | 17 | ||
QKZDEF | Definition of Quality Score Classes | QQKZDEF | CHAR | 2 | TQ56 | |
KLASSE_A | Absolute Frequency of Quality Score Class A | QKLASSE_A | INT4 | 10 | ||
KLASSE_B | Absolute Frequency of Quality Score Class B | QKLASSE_B | INT4 | 10 | ||
KLASSE_C | Absolute Frequency of Quality Score Class C | QKLASSE_C | INT4 | 10 | ||
KLASSE_D | Absolute Frequency of Quality Score Class D | QKLASSE_D | INT4 | 10 | ||
KLASSE_E | Absolute Frequency of Quality Score Class E | QKLASSE_E | INT4 | 10 | ||
ZHLLOSQKZ | Number of Summarized Inspection Lots for Quality Score | QZHLLOSQKZ | INT4 | 10 | ||
SUMQKZ | Total of Quality Scores | QSUMQKZ | FLTP | 16 | ||
SUM2QKZ | Square Total of Quality Score | QSUM2QKZ | FLTP | 16 | ||
ZHLLOSANTL | Number of Summarized Lots (Including Share of Scrap) | QZHLLOSANT | INT4 | 10 | ||
SUMANTL | Total Share of Nonconforming Units | QSUMANTL | FLTP | 16 | ||
SUM2ANTL | Square Total of the Share of Nonconforming Units | QSUM2ANTL | FLTP | 16 | ||
ZHLLOSDR | Number of Summarized Inspection Lots (Lead Time) | QZHLLOSDR | INT4 | 10 | ||
SUMDLZT | Total Lead Time | QSUMDLZT | FLTP | 16 | ||
SUM2DLZT | Square Total of Lead Time | QSUM2DLZT | FLTP | 16 | ||
SMGSCHL | Cumulated Inspected and Defective Quantity | QSMGSCHL | QUAN | 17 |