This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The table T343XYZ (Storage Bin Structure for X, Y, Z assignment to Storage bins) is a standard table in SAP ERP. It belongs to the package LESI.
Table | T343XYZ |
Short Text | Storage Bin Structure for X, Y, Z assignment to Storage bins |
Package | LESI |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | * |
LGNUM | ✔ | Warehouse Number / Warehouse Complex | LGNUM | CHAR | 3 | T300 |
LGTYP | ✔ | Storage Type | LGTYP | CHAR | 3 | T301 |
LFDNR | ✔ | Sequence number | LVS_LFDNR | CHAR | 3 | |
SCHAB | Format of bin coordinate for automatic creation | T343_SCHAB | CHAR | 10 | * | |
STRUK | Structure of storage bins for automatic creation | T343_STRUK | CHAR | 10 | * | |
STAWE | Start value of storage bins for automatic creation | T343_STAWE | CHAR | 10 | * | |
ENDWE | End value of storage bins for automatic creation | T343_ENDWE | CHAR | 10 | * | |
INCRE | Increment for bins for automatic creation | T343_INCRE | CHAR | 10 | * | |
X_ZERO | X Coordinate of the start bin | T343XYZ_XZERO | QUAN | 10 | ||
Y_ZERO | Y Coordinate of the start bin | T343XYZ_YZERO | QUAN | 10 | ||
Z_ZERO | Z Coordinate of the start bin | T343XYZ_ZZERO | QUAN | 10 | ||
XSTRU | Pointer to Structure for X | T343XYZ_XSTRU | CHAR | 1 | ||
YSTRU | Pointer to Structure for Y | T343XYZ_YSTRU | CHAR | 1 | ||
ZSTRU | Pointer to Structure for Z | T343XYZ_ZSTRU | CHAR | 1 | ||
XINCR | Increment in X-Direction | T343XYZ_XINCR | QUAN | 10 | ||
YINCR | Increment in Y-Direction | T343XYZ_YINCR | QUAN | 10 | ||
ZINCR | Increment in Z-Direction | T343XYZ_ZINCR | QUAN | 10 | ||
ANGLE | Angle for the orientation of a storage type in degrees | T343XYZ_ANGLE | DEC | 4 | ||
XINCX | Increment in X-Direction calculated by angle and X-Increment | T343XYZ_XINCX | QUAN | 10 | ||
YINCX | Increment in Y-Direction calculated by angle and X-Increment | T343XYZ_YINCX | QUAN | 10 | ||
XINCY | Increment in X-Direction calculated by angle and Y-Increment | T343XYZ_XINCY | QUAN | 10 | ||
YINCY | Increment in Y-Direction calculated by angle and Y-Increment | T343XYZ_YINCY | QUAN | 10 | ||
LZONE | Zone | LAGP_LZONE | CHAR | 10 |