This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The Function Module CBIH_MP30_MP_CREATE (EHS: Anlegen von Messprojektdaten) is a standard Function Module in SAP ERP and is part of the function group CBIH_MP30 within the package CBIH.
Function Module | CBIH_MP30_MP_CREATE |
Short Text | EHS: Anlegen von Messprojektdaten |
Function Group | CBIH_MP30 |
Package | CBIH |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
I_ADDINF | LIKE | RCGADDINF | Zusatzinformationen zum Objekt | |
I_FLG_CHECK_CLVALUE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungsdaten prüfen |
I_FLG_CHECK_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Daten nur überprüfen |
I_FLG_FILL_EXTERROR | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Erweiterte FehlerInfoTabelle befüllen |
I_FLG_KEY_DATE_SWITCH_ONLY | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. nur Stichtag und Änderungsnummer wechseln |
I_FLG_MJ_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messauftrag anlegen |
I_FLG_MJ_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 Messauftrag |
I_FLG_MJ_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 Messauftrag |
I_FLG_MJ_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messauftrag |
I_FLG_MJ_REFERENCE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Referenzmessung anlegen |
I_FLG_MJ_VALUES | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messwerte anlegen |
I_FLG_MJ_WORKAREA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zuordnung Arbeitsber.-Messauftrag anlegen |
I_FLG_MP_EQUIPMENT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Geräte für Projekt anlegen |
I_FLG_MP_HEADER | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messprojektkopf anlegen |
I_FLG_MP_HEADER_LTXT1 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 1 zu Messprojektkopf |
I_FLG_MP_HEADER_LTXT2 | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext 2 zu Messprojektkopf |
I_FLG_MP_HEADER_VAL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Bewertungen zu Messprojektkopf |
I_FLG_MP_PLAN | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Projektplan anlegen |
I_FLG_MP_PLAN_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext Projektplan |
I_FLG_MP_PLMET | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Messplan Messverfahren anlegen |
I_FLG_MP_WA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Zuordn. Arbeitsbereich-Projekt anlegen |
I_FLG_MP_WA_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz. Langtext Arbeitsbereich |
I_VALFR | LIKE | RCGADDINF-VALDAT | untere Zeitintervallgrenze | |
I_VALTO | LIKE | RCGADDINF-VALDAT | obere Zeitintervallgrenze |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
E_FLG_ERROR | TYPE | ESP1_BOOLEAN | Kennz. Fehler beim Anlegen eines Satzes | |
E_FLG_LOCKFAIL | TYPE | ESP1_BOOLEAN | Kennz. Sperre auf mind. einen Satz fehlgeschl. | |
E_FLG_WARNING | TYPE | ESP1_BOOLEAN | Kennz. Warnung beim Anlegen eines Satzes |
This function module does not define any CHANGING parameters.
These are the TABLE parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
X_API_MP_TAB | TYPE | CIHMP_MP_API_TAB_TYPE | Messprojektdaten |
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
INTERNAL_ERROR | Interner Programmfehler |
INTERVAL_ACCESS_ERROR | Zugriff auf Zeitintervalle ist fehlerhaft |
NO_OBJECT_SPECIFIED | Kein anzulegendes Objekt angegeben |
PARAMETER_ERROR | Kennzeichen gesetzt aber zugeh. Daten fehlen |