This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The Function Module CY_ADD_PERIODS (Adds a number of periods to the current one) is a standard Function Module in SAP ERP and is part of the function group CYCP within the package CY.
Function Module | CY_ADD_PERIODS |
Short Text | Adds a number of periods to the current one |
Function Group | CYCP |
Package | CY |
Module Type | Normal Module |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
CALENDAR_ID | LIKE | RC65A-KALID | Calendar ID | |
FISCAL_YEAR_VARIANT | LIKE | RC65A-PERIV | Fiscal year variant | |
NUMBER_OF_PERIODS | LIKE | Number of periods to be added to the current one | ||
PERIOD_TYPE | LIKE | RC65A-DATE_TYPE | Period type to write RESULTING_PERIOD |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
FIRST_DATE | LIKE | SY-DATUM | First day of the calculated period | |
LAST_DATE | LIKE | SY-DATUM | Last day of the calculated period | |
RESULTING_PERIOD | LIKE | RC65A-DATEFROM | Calculated period |
This function module does not define any CHANGING parameters.
This function module does not define any TABLE parameters.
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
CALENDAR_BUFFER_NOT_LOADABLE | sic! |
DATE_AFTER_RANGE | Date after the defined range of the factory cal. |
DATE_BEFORE_RANGE | Date before the defined range of the fact. cal. |
DATE_INVALID | Date not correct |
FACTORYDATE_AFTER_RANGE | Factory date later than range in calendar |
FACTORYDATE_BEFORE_RANGE | Factory date earlier than range in calendar |
FACTORYDATE_INVALID | Factory date not valid |
FACTORY_CALENDAR_ID_MISSING | Calendar ID needed for conversion |
FACTORY_CALENDAR_NOT_FOUND | Factory calendar not found |
FISCAL_YEAR_VARIANT_MISSING | sic! |
INVALID_PERIOD_TYPE | Period type not valid |
NOT_AN_INTEGER | NUMBER_OF_PERIODS doesn't contain an integer |
T009B_NOTFOUND | Fiscal year variant not found in table T009B |
T009_NOTFOUND | Fiscal year variant not found in table T009 |