This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The Function Module FUNC_LOCATION_ISU_2 (IS-U: API für Techn.Platz: View IFLO mit PERFORM ON COMMIT verbuchen) is a standard Function Module in SAP ERP and is part of the function group ILOU within the package ILOM.
Function Module | FUNC_LOCATION_ISU_2 |
Short Text | IS-U: API für Techn.Platz: View IFLO mit PERFORM ON COMMIT verbuchen |
Function Group | ILOU |
Package | ILOM |
Module Type | Remote-Enabled |
These are the IMPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
AUTH_TCODE | LIKE | SY-TCODE | SY-TCODE | Transaktionscode für Berechtigungsprüfungen |
IFLO_WA | LIKE | IFLO | zu verbuchender Technischer Platz | |
UPDATE_ASYNCHRON | LIKE | IREF-IIND | 'X' | X - Update asynchron - IN UPDATE TASK |
UPDATE_INDICATOR | LIKE | RIUPD-INDUPD | 'U' | Update-Indikator (I/U) |
WITH_DIALOG_SCREEN | LIKE | IREF-IIND | 'X' | X - Dialogbilder und Meldungen erlaubt |
These are the EXPORTING parameters of this function module.
Parameter Name | Type | Associated Type | Default Value | Short Text |
---|---|---|---|---|
IFLO_BA | LIKE | IFLO | Workarea des Platzes, so wie verbucht |
This function module does not define any CHANGING parameters.
This function module does not define any TABLE parameters.
These are the Exceptions of this function module.
Exception Name | Short Text |
---|---|
ERROR_IN_CUSTUMIZING | Customizing fehlerhaft oder unvollständig |
ERROR_IN_MASTER_DATA | Sonstiger Fehler in Datenfeldern von IFLO_WA |
FUNC_LOCATION_NOT_FOUND | Platz nicht auf DB obwohl UPDATE_INDICATOR - U |
FUNC_LOCATION_NOT_IN_BUFFER | Platz nicht im Puffer und UPDATE_INDICATOR - I |
MEASUREM_POINT_LOCKED | Meßpunkt durch anderen Benutzer gesperrt |
NO_AUTHORITY | Keine Berechtigung |
STATUS_CHECK_FUNC_LOCATION | Vorgang nicht möglich wegen Status IFLO_WA-TPLNR |
STATUS_CHECK_SUPERIOR_LOC | Vorgang nicht möglich wegen Status IFLO_WA-TPLMA |
SUPERIOR_LOCATION_NOT_FOUND | Übergeordneter Platz existiert nicht |
SUPERIOR_LOCATION_RECURSIVE | IFLO_WA-TPLMA wegen Rekursivität abgelehnt |