This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table CRCA (Work Center Capacity Allocation) is a standard table in SAP ERP. It belongs to the package CR.
Table | CRCA |
Short Text | Work Center Capacity Allocation |
Package | CR |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
OBJTY | ✔ | Object types of the CIM resource | CR_OBJTY | CHAR | 2 | |
OBJID | ✔ | Object ID of the resource | CR_OBJID | NUMC | 8 | CRID |
CANUM | ✔ | Capacity allocation number | CR_CAPNUM | NUMC | 4 | |
BEGDA | Start Date | BEGDATUM | DATS | 8 | ||
ENDDA | End Date | ENDDATUM | DATS | 8 | ||
AEDAT_KAPA | Changed on | AEDTM | DATS | 8 | ||
AENAM_KAPA | User Name | USRNAME | CHAR | 12 | ||
KAPID | Capacity ID | KAPID | NUMC | 8 | KAKO | |
FORK1 | Formula for setup capacity requirements | AP_FORM_K1 | CHAR | 6 | TC25 | |
FORK2 | Formula for processing capacity requirements | AP_FORM_K2 | CHAR | 6 | TC25 | |
FORK3 | Formula for teardown capacity requirements | AP_FORM_K3 | CHAR | 6 | TC25 | |
FORKN | Formula for cap. reqmts. for other types of int. processing | AP_FORM_KN | CHAR | 6 | TC25 | |
PROZT | Percentage share of available capacity | AP_PROZ_KA | NUMC | 3 | ||
VERT1 | Distribution of capacity requirements (Planned/prod.order) | CR_VERT1 | CHAR | 8 | TC29 | |
VERT2 | Key for distributing requirements over processing time | CR_VERT2 | CHAR | 8 | TC29 | |
VERT3 | Distribution key for teardown requirements | CR_VERT3 | CHAR | 8 | TC29 | |
VERTN | Distr.cap.reqmts (plant maint.,process order, network) | CR_VERTN | CHAR | 8 | TC29 | |
CAROL | Role of work center capacity | CR_CAPROLE | CHAR | 40 | ||
ISTBED_KZ | Calculation of actual capacity requirements | CY_ISTBEDKZ | CHAR | 1 | ||
VGWT1 | Actual requirements for operation segment setup | CY_VGWT1 | CHAR | 6 | * | |
VGWT2 | Actual requirements for operation segment processing | CY_VGWT2 | CHAR | 6 | * | |
VGWT3 | Actual capacity requirements for operation segment teardown | CY_VGWT3 | CHAR | 6 | * | |
VGWTN | Actual capacity requirements for in-house processing | CY_VGWTN | CHAR | 6 | * | |
CAP_BACKFLUSH_SU | Control: Calc. of Remaining Req./Duration After Confirmation | CAP_BACKFLUSH | NUMC | 1 | ||
CAP_BACKFLUSH_PR | Control: Calc. of Remaining Req./Duration After Confirmation | CAP_BACKFLUSH | NUMC | 1 | ||
CAP_BACKFLUSH_TD | Control: Calc. of Remaining Req./Duration After Confirmation | CAP_BACKFLUSH | NUMC | 1 |