This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table OIB01 (Conversion Group) is a standard table in SAP ERP. It belongs to the package OIL.
Table | OIB01 |
Short Text | Conversion Group |
Package | OIL |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
UMRSL | ✔ | Conversion Group (Oil, Natural Gas,..) | OIB_UMRSL | CHAR | 4 | |
PDTYP | Oil product type | OIB_PDTYP | CHAR | 1 | ||
BSTMP | Oil/gas standard/base temperature | OIB_BSTMP | FLTP | 16 | ||
BSTEH | Oil/gas standard/base temperature unit | OIB_BSTEH | UNIT | 3 | T006 | |
WQTYL | Lower warning tolerance limit for manual entries (in %) | OIB_WQTYL | FLTP | 16 | ||
WQTYH | Upper warning tolerance limit for manual entries (in %) | OIB_WQTYH | FLTP | 16 | ||
EQTYL | Lower Tolerance Limit for Manual Quantity Entries (in %) | OIB_EQTYL | FLTP | 16 | ||
EQTYH | Upper Tolerance Limit for Manual Quantity Entries (in %) | OIB_EQTYH | FLTP | 16 | ||
DNTYP | Density Type | OIB_DNTYP | CHAR | 1 | ||
VCFLN | Volume correction factor | OIB_VCFLN | CHAR | 1 | ||
MCFI | Meter correction factor indicator | OIB_MCFI | CHAR | 1 | ||
PDCL | Oil/Gas product conversion class | OIB_PDCL | CHAR | 2 | ||
HVTYP | Heating value type | OIB_HVTYP | CHAR | 2 | ||
BPRESH | Natural Gas Base Pressure for Combustion (Heating Value) | OIB_BPRESH | FLTP | 16 | ||
BPRESHEH | Natural gas std/base press.: combustion (heat. value): unit | OIB_BPRESHEH | UNIT | 3 | T006 | |
BSTMPH | Natural Gas Base Temperature of Combustion (Heating Value) | OIB_BSTMPH | FLTP | 16 | ||
BSTMPHEH | Natural gas std/base temp.: combustion (heat. value): unit | OIB_BSTMPHEH | UNIT | 3 | T006 | |
EXT_PROG_VERSION | Supported version of external routines | OIB_EXT_VERSION | CHAR | 1 | ||
BPRESV | Oil/gas standard/base pressure:metering (volume, density) | OIB_BPRESV | FLTP | 16 | ||
BPRESVEH | Oil/gas standard/base pres.:metering (volume, density): unit | OIB_BPRESVEH | UNIT | 3 | T006 | |
BTMPVP | Oil/gas standard/base temperature (vapor pressure) | OIB_BTMPVP | FLTP | 16 | ||
BTMPVPEH | Oil/gas standard/base temperature unit (vapor pressure) | OIB_BTMPVPEH | UNIT | 3 | T006 | |
CHGS | Conversion handling for gases | OIB_CHGS | CHAR | 1 | ||
CHLQ | Conversion handling for liquid products | OIB_CHLQ | CHAR | 1 | ||
EXTDNUNIT | Unit for densities of petroleum products and natural gas | OIB_DNEH | UNIT | 3 | T006 | |
EXTHVUNIT | Heating value unit | OIB_HVEH | UNIT | 3 | T006 | |
EXTIND | External functions ind. (API c-codes, etc.) | OIB_EXTIND | CHAR | 1 | ||
VCFLN_LPG | Volume correction factor LPG | OIB_VCFLN_LPG | CHAR | 1 | ||
BSDNEH | Base density unit (at standard reference conditions) | OIB_BSDNEH | UNIT | 3 | T006 | |
BSHVEH | Base heating value unit (at standard reference conditions) | OIB_BSHVEH | UNIT | 3 | T006 | |
TDTHV | Test density/test heating value - parameter handling | OIB_TDTHV | CHAR | 1 | ||
BDBHV | Base density / base heating value parameter handling | OIB_BDBHV | CHAR | 1 | ||
AROMATICS | Industrial aromatic hydrocarbons: Type | OIB_AROMATICS | CHAR | 2 | ||
BHVCLS | Heating value class (calorific value class) | OIB_HVCLS | CHAR | 2 | ||
IDGAS | Indicator for SAP natural gas routine (ideal/real gas) | OIB_IDGAS | CHAR | 1 | ||
RFC_RELEASE | Release indicator for external (RFC) calls to QCI | OIB_RELEASE | CHAR | 1 |