This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table QDPA (Sampling scheme-instructions) is a standard table in SAP ERP. It belongs to the package QDSE.
Table | QDPA |
Short Text | Sampling scheme-instructions |
Package | QDSE |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
STPRPLAN | ✔ | Sampling Scheme | QSTPRPLAN | CHAR | 3 | QDPK |
ZAEHLPOS | ✔ | Sequential Counter for Items in a Sampling Scheme | QZAEHLPOS | INT2 | 5 | QDPP |
PRSCHAERFE | ✔ | Inspection Severity | QPRSCHAERP | NUMC | 3 | QDEP |
ZAEHLANW | ✔ | Seqntl Counter for Sampling Instructions in Sampling Scheme | QZAEHLANW | INT2 | 5 | |
LOSUMF | Lot Size in Sampling Scheme | QLOSUMF | FLTP | 16 | ||
LOSUMFNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
STPRUMF | Number of Sampling Units in a Sample | QSTPRUMFP | INT4 | 10 | ||
STPRANZ | Number of Samples for Independent Multiple Samples | QSTPRANZ7 | INT1 | 3 | ||
ANNAHMEZ | Acceptance Number | QANNAHMEZP | INT2 | 5 | ||
RUECKWEZ | Rejection Number | QRUECKWEZP | INT2 | 5 | ||
ANNAHMEZ2 | Acceptance Number for 2nd Sample | QANNAHMZP2 | INT2 | 5 | ||
RUECKWEZ2 | Rejection Number for the 2nd Sample | QRUECKWZP2 | INT2 | 5 | ||
ANNAHMEZ3 | Acceptance Number for 3rd Sample | QANNAHMZP3 | INT2 | 5 | ||
RUECKWEZ3 | Rejection Number for the 3rd Sample | QRUECKWZP3 | INT2 | 5 | ||
ANNAHMEZ4 | Acceptance Number for 4th Sample | QANNAHMZP4 | INT2 | 5 | ||
RUECKWEZ4 | Rejection Number for the 4th Sample | QRUECKWZP4 | INT2 | 5 | ||
ANNAHMEZ5 | Acceptance Number for 5th Sample | QANNAHMZP5 | INT2 | 5 | ||
RUECKWEZ5 | Rejection Number for the 5th Sample | QRUECKWZP5 | INT2 | 5 | ||
ANNAHMEZ6 | Acceptance Number for 6th Sample | QANNAHMZP6 | INT2 | 5 | ||
RUECKWEZ6 | Rejection Number for the 6th Sample | QRUECKWZP6 | INT2 | 5 | ||
ANNAHMEZ7 | Acceptance Number for 7th Sample | QANNAHMZP7 | INT2 | 5 | ||
RUECKWEZ7 | Rejection Number for the 7th Sample | QRUECKWZP7 | INT2 | 5 | ||
KFAKTOR | K-Factor for a Variable Inspection | QKFAKTORP | FLTP | 16 | ||
KFAKTORNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 |