This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table T5CAG (PC Method Definitions) is a standard table in SAP ERP. It belongs to the package PK02.
Table | T5CAG |
Short Text | PC Method Definitions |
Package | PK02 |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
MOLGA | ✔ | Country Grouping | MOLGA | CHAR | 2 | T500L |
APPLI | ✔ | Subapplication code | P02_APPLI | CHAR | 2 | T5CBY |
PPLAN | ✔ | Processing schedule | P02_PPLAN | CHAR | 2 | T5CA4 |
VALTY | ✔ | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 |
METHD | ✔ | PC method type | P02_METHD | CHAR | 2 | T5CA6 |
EGMTD | ✔ | Employee grouping for PC methods | P02_EGMTD | CHAR | 2 | T5CAI |
MTVAR | ✔ | PC method variant | P02_MTVAR | CHAR | 2 | |
NLINE | ✔ | Line number | P02_NLINE | NUMC | 3 | |
LINTY | Processing schedule: Line type | P02_LINTY | CHAR | 3 | ||
OPERA | PC operation | P02_OPERA | CHAR | 2 | T5CAE | |
VTY01 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR01 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY02 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR02 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY03 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR03 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY04 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR04 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY05 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR05 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY06 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR06 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY07 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR07 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY08 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR08 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY09 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR09 | Value within processing control | P02_VAL | CHAR | 18 | ||
VTY10 | PC Value Type | P02_VALTY | CHAR | 4 | T5CA2 | |
PAR10 | Value within processing control | P02_VAL | CHAR | 18 | ||
EOLP0 | Processing schedule: End of line processing | P02_EOLP | CHAR | 2 | ||
EOLA0 | Processing schedule: End of line key | P02_EOLA | NUMC | 3 | ||
EOLP1 | Processing schedule: End of line processing | P02_EOLP | CHAR | 2 | ||
EOLA1 | Processing schedule: End of line key | P02_EOLA | NUMC | 3 | ||
EOLP2 | Processing schedule: End of line processing | P02_EOLP | CHAR | 2 | ||
EOLA2 | Processing schedule: End of line key | P02_EOLA | NUMC | 3 | ||
EOLP3 | Processing schedule: End of line processing | P02_EOLP | CHAR | 2 | ||
EOLA3 | Processing schedule: End of line key | P02_EOLA | NUMC | 3 | ||
EOLP4 | Processing schedule: End of line processing | P02_EOLP | CHAR | 2 | ||
EOLA4 | Processing schedule: End of line key | P02_EOLA | NUMC | 3 |