This bundle includes Echo Dot (3rd Gen) Charcoal and Philips Hue White A19 Medium Lumen Smart Bulb, 1100 Lumens. Built in Smart Home hub. Ask Alexa to control Zigbee-compatible devices. No additional Philips Hue hub required. Two choices for easy smart lighting - Start setting the mood with Hue Smart bulbs and your Echo device, supporting up to 5 Hue Bluetooth & Zigbee smart bulbs. Add the Hue Hub for whole-home smart lighting (up to 50 light points) and bonus features.
Check it out on amazon.com →The table CPPECNTL (General iPPE Customizing) is a standard table in SAP ERP. It belongs to the package CPPEENG0C.
Table | CPPECNTL |
Short Text | General iPPE Customizing |
Package | CPPEENG0C |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | * |
EXPL_OPTION | Explosion Type for Variants and Modes | PPE_EXPL_OPTION | CHAR | 1 | ||
CLASS_ASSIGN | General Settings for Class Use | PPE_CLASS_ASSIGN | CHAR | 1 | ||
ANAL_PRIO | Take Evaluation Priority of Variants into Consideration | PPE_ANAL_PRIO | CHAR | 1 | ||
COL_OFFSET | Position of the Color Supplement Key in Material | PPE_COL_OFFSET | INT1 | 3 | ||
COL_LEN | Length of Color Supplement Key | PPE_COL_LEN | INT1 | 3 | ||
EFFPARAM | Effectivity Parameters | PPE_EFFP | CHAR | 25 | ||
EFF_RPM | Check Parameter Effectivities for the RPM | PVS_EFF_RPM | CHAR | 1 | ||
ATINN | Characteristic for Start-Up Parameters | PPE_VSPMM | NUMC | 10 | * | |
PROPCODE_FLG | Start-Up Parameters Active | PPE_PROPCODEFLG | CHAR | 1 | ||
LOGSYS_CHECK | System Reaction When Checking the Logical System | PVS_LOGSYS_CHECK | CHAR | 1 | ||
IDOCSIZE | iPPE / BAPI: Number of iPPE Objects per IDOC | PPE_IDOCSIZE | INT4 | 10 | ||
PLANT_LO | Description of Effectivity Parameter: Plant | PPE_PLANT_LO | CHAR | 20 | ||
DATE_LO | Description of Effectivity Parameter: Date | PPE_DATE_LO | CHAR | 20 | ||
CLASS_LO | Description of Effectivity Parameter: Class | PPE_CLASS_LO | CHAR | 20 | ||
CLASSTY_LO | Effectivity Parameters: Class Type | PPE_CLASSTY_LO | CHAR | 20 | ||
CD_SWITCH_OFF | Switch Off the Change Documents | PPE_CD_SWITCH_OFF | CHAR | 1 | ||
WFE_SWITCH_OFF | Switch Off Workflow Events | PPE_WFE_SWITCH_OFF | CHAR | 1 | ||
TDM_SWITCH_ON | Switch On TDM Events | PPE_TDM_SWITCH_ON | CHAR | 1 | ||
KLART | Class Type Standard Value | PPE_KLASSENART_DEFAULT | CHAR | 3 | * | |
KNOBJ_ADV_EDIT | Extended Dependency Editor | PPE_KNOBJ_ADV_EDIT | CHAR | 1 | ||
VSP_ATNAM | Characteristic Name for the Start-Up Parameter | PPE_VSPEM | CHAR | 30 | ||
CREADAT | Date of Application | PVS_ANDAT | DATS | 8 | ||
CREABY | User who created record | PVS_ANNAM | CHAR | 12 | ||
CHNGDAT | Date of Last Change | PVS_AEDAT | DATS | 8 | ||
CHNGBY | Name of Person Who Changed Object | PVS_AENAM | CHAR | 12 | ||
LOGSYS | Logical system | LOGSYS | CHAR | 10 | * |