This bundle contains Amazon Fire TV Stick Lite and Mission USB Power Cable. The USB power cable eliminates the need to find an AC outlet near your TV by powering Amazon Fire TV directly from your TV's USB port. Includes special power management circuitry that enhances the peak power capability of the USB port by storing excess energy and then releasing it as needed.
Check it out on amazon.com →The table QMSP (QM: material specification) is a standard table in SAP ERP. It belongs to the package QM.
Table | QMSP |
Short Text | QM: material specification |
Package | QM |
Table Type | Transparent Table |
Field Name | Key | Description | Data Element | Type | Length | Check Table |
---|---|---|---|---|---|---|
MANDT | ✔ | Client | MANDT | CLNT | 3 | T000 |
MATNR | ✔ | Material Number | MATNR | CHAR | 18 | MARA |
ZAEHLER | ✔ | Internal Counter for DB Objects | Q_COUNT | NUMC | 6 | |
DATUV | Date, for Which the Change Is Planned | QPLANDAT | DATS | 8 | ||
ATINN | Internal characteristic | ATINN | NUMC | 10 | * | |
WERKS | Plant for the Master Inspection Characteristic | QZAEHLER | CHAR | 4 | ||
MKMNR | Master Inspection Characteristics | QMERKNR | CHAR | 8 | QPMK | |
VERSION | Version Number of the Master Inspection Characteristic | QVERSNRMK | CHAR | 6 | ||
SOLLWERT | Target Value for a Quantitative Characteristic | QSOLLWERTE | FLTP | 16 | ||
SOLLWNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERANZOB | Upper Specification Limit | QTOLOB | FLTP | 16 | ||
TOLOBNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
TOLERANZUN | Lower Tolerance Limit | QTOLUN | FLTP | 16 | ||
TOLUNNI | Value Not Initial if Set | QNINITIAL | CHAR | 1 | ||
MASSEINHSW | Unit of Measurement, in Which Quantitative Data Is Stored | QMASSEH | UNIT | 3 | T006 | |
STELLEN | Number of Places to the Right of a Decimal Point (Accuracy) | QSTELLEN | INT1 | 3 | ||
AUSWMENGE1 | Assigned Code Group or Selected Set | QCGRAUSW | CHAR | 8 | ||
AUSWMGWRK1 | Plant of the Assigned Selected Set | QWERKAUSW | CHAR | 4 | T001W | |
VERSION1 | Version Number | QVERSNR | CHAR | 6 | ||
STEUERKZ | Cntrl Indicator String for Insp. Char./Master Insp. Char. | QMKCONTROL | CHAR | 30 | ||
STICHPRVER | Sampling Procedure in Inspection Characteristic | QSTICHVERF | CHAR | 8 | QDSV | |
PROBEMGEH | Sample Unit of Measure | QPROBME | UNIT | 3 | T006 | |
PRUEFEINH | Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) | QPROBEFAK | DEC | 5 | ||
REFERAMK | Values Are Referenced in the Specification | QREFERAMK | CHAR | 1 | ||
STICHPRPP | Sampling Procedure for Inspection Point Processing | QSTICHPNKT | CHAR | 8 | QDSV | |
QERGDATH | Planned Results Data Origin | QERGDATHPL | CHAR | 2 | TQ73 | |
CHARACT_ID1 | Characteristic Description for Quality Data Exchange | QCHARACT_ID1 | CHAR | 40 |